orifice DN 10 - 250
pressure range 0 - 1500 psi
connection thread / flange
function NC
valve normally closed
function NO
valve normally open
The valves' technical design is based on media and application requirements. This can lead to deviations from the general specifications shown on the data sheet with regards to the design, sealing materials and characteristics.
design pressure balanced, with spring return
function NC - normally closed, NO - normally open
body materials aluminium, brass, galvanized steel, nickel plated brass, nickel plated steel, without non-ferrous metals, stainless steel
seal materials NBR, PTFE, FPM, PU, PE, CR, EPDM, special seal materials
media gaseous, liquid, gelatinous, highly viscous, pasty, contaminated, aggressive, coolant
actuation pneumatic actuation via 3/2- or 5/2-way pilot valve
hydraulic actuation via 4/2-way control valve
pilot valve interface NAMUR / ISO 1
nominal voltage DC 24 V / AC 110 V / AC 230 V
electrical connection pilot valve plug acc. DIN EN 175301-803, form B, LED
enclosure protection IP 65
energized duty rating ED 100%
flow direction A B
B A (Δp 16 bar max.)
vacuum leak rate < 10-6 mbar·l·s-1
options function NO, limit switches, manual override, special voltage, coil M 12 x 1, pilot valve, damping, approvals, connections for sensor or pressure gauge, explosion-proof
co-ax type orifice
mm
connection
thread NPT
connection
flange ANSI
pressure range
psi
Cv
value
media
temperature
ambient
temperature
switch time ms
open/close
CFM 08 DN 08 3/8 - 0 - 600 1.9 32°F ... 140°F 32°F ... 140°F -
VMK 10 DN 10 1/4 - 3/4 - 0 - 150 / 600 / 900 2.9 -4°F ... 320°F -4°F ... 320°F 30-3000 / 50-3000
VMK / VFK 15 DN 15 3/8 - 3/4 150/600/1500 0 - 150 / 600 / 900 / 1500 6.8 -4°F ... 320°F -4°F ... 320°F 50-3000 / 50-3000
VMK / VFK 20 DN 20 3/4 - 1 1/4 150/600/1500 0 - 150 / 600 / 900 / 1500 10.1 -4°F ... 320°F -4°F ... 320°F 50-3000 / 50-3000
VMK / VFK 25 DN 25 1 - 1 1/2 150/600/1500 0 - 150 / 600 / 900 / 1500 14.0 -4°F ... 320°F -4°F ... 320°F 50-3000 / 50-3000
VMK / VFK 32 DN 32 1 1/4 - 1 1/2 150/600/1500 0 - 150 / 600 / 900 / 1500 23.0 -4°F ... 320°F -4°F ... 320°F 100-3000 / 100-3000
VMK / VFK 40 DN 40 1 1/2 - 2 1500 0 - 900 / 1500 35.7 -4°F ... 320°F -4°F ... 320°F 100-3000 / 100-3000
VMK / VFK 50 DN 50 2 900/1500 0 - 900 / 1500 49.5 -4°F ... 320°F -4°F ... 320°F 150-3000 / 150-3000
VSV-M / VSV-F 40 DN 40 1 1/2 - 2 150/600 0 - 150 / 600 35.7 -4°F ... 320°F -4°F ... 320°F 100-3000 / 100-3000
VSV-M / VSV-F 50 DN 50 2 150/600 0 - 150 / 600 49.5 -4°F ... 320°F -4°F ... 320°F 150-3000 / 150-3000
VSV-F 65 DN 65 - 150/600 0 - 150 / 600 78.2 -4°F ... 320°F -4°F ... 320°F 200-3000 / 200-3000
VSV-F 80 DN 80 - 150/600 0 - 150 / 600 103.5 -4°F ... 320°F -4°F ... 320°F 200-3000 / 200-3000
VSV-F 100 DN 100 - 150/600 0 - 150 / 600 161.0 -4°F ... 320°F -4°F ... 320°F 300-3000 / 300-3000
VSV-F 125 DN 125 - 150/600 0 - 150 / 600 227.7 -4°F ... 320°F -4°F ... 320°F 400-3000 / 400-3000
VSV-F 150 DN 150 - 150/600 0 - 150 / 600 315.1 -4°F ... 320°F -4°F ... 320°F 600-3000 / 600-3000
VSV-F 200 DN 200 - 150 0 - 150 517.5 -4°F ... 320°F -4°F ... 320°F 800-3000 / 800-3000
VSV-F 250 DN 250 - 150 0 - 150 747.5 -4°F ... 320°F -4°F ... 320°F 1500-3000 / 1500-3000
FCF 65 DN 65 - 150/600 0 - 150 / 600 123.1 -4°F ... 320°F -4°F ... 320°F 250-3000 / 400-3000
FCF-K 65 DN 65 - 150/600 0 - 150 / 600 112.7 -4°F ... 320°F -4°F ... 320°F 250-3000 / 400-3000
FCF 80 DN 80 - 150/600 0 - 150 / 600 153.0 -4°F ... 320°F -4°F ... 320°F 300-3000 / 300-3000
FCF-K 80 DN 80 - 150/600 0 - 150 / 600 140.3 -4°F ... 320°F -4°F ... 320°F 300-3000 / 350-3000
FCF 100 DN 100 - 150/600 0 - 150 / 600 247.3 -4°F ... 320°F -4°F ... 320°F 450-3000 / 300-3000
FCF-K 100 DN 100 - 150/600 0 - 150 / 600 222.0 -4°F ... 320°F -4°F ... 320°F 450-3000 / 300-3000
FCF 125 DN 125 - 150/600 0 - 150 / 600 261.1 -4°F ... 320°F -4°F ... 320°F 700-3000 / 450-3000
FCF-K 125 DN 125 - 150/600 0 - 150 / 600 254.2 -4°F ... 320°F -4°F ... 320°F 700-3000 / 450-3000
co-ax type connection standard 1 inductive
limit switch
2 inductive
limit switches
1 mechanical
limit switch
manual
override
CFM 08 thread 3.15" - - via pilot valve
VMK 10 thread 6.30" 7.09" 7.09" - via pilot valve
VMK / VFK 15 thread / flange 7.32" / 9.57" 8.35" / 10.59" 8.35" / 10.59" 8.11" / 10.35" via pilot valve
VMK / VFK 20 thread / flange 8.50" / 10.63" 9.25" / 11.38" 9.25" / 11.38" 9.33" / 11.46" via pilot valve
VMK / VFK 25 thread / flange 9.69" / 11.89" 10.24" / 12.44" 10.24" / 12.44" 10.63" / 12.83" via pilot valve
VMK / VFK 32 thread / flange 10.59" / 12.80" 10.87" / 13.07" 10.87" / 13.07" 11.97" / 14.17" via pilot valve
VMK / VFK 40 thread / flange 12.28" / 15.16" 12.28" / 15.16" 12.28" / 15.16" - via pilot valve
VMK / VFK 50 thread / flange 12.28" / 15.16" 12.28" / 15.16" 12.28" / 15.16" - via pilot valve
VSV-M / VSV-F 40 thread / flange 10.91" / 10.35" 12.28" / 16.42" 12.28" / 16.42" - / 15.35" via pilot valve
VSV-M / VSV-F 50 thread / flange 11.97" / 15.91" 12.99" / 16.93" 12.99" / 17.32" 17.48" / - via pilot valve
VSV-F 65 flange 21.18" 21.18" 21.18" - via pilot valve
VSV-F 80 flange 22.83" 22.83" 22.83" - via pilot valve
VSV-F 100 flange 23.62" 23.62" 23.62" - via pilot valve
VSV-F 125 flange 27.44" 27.44" 27.44" - via pilot valve
VSV-F 150 flange 30.35" 30.35" 30.35" - via pilot valve
VSV-F 200 flange 36.42" 36.42" 36.42" - via pilot valve
VSV-F 250 flange 40.75" 40.75" 40.75" - via pilot valve
FCF 65 flange 9.45" 9.45" 9.45" - via pilot valve
FCF-K 65 flange 6.69" - - - via pilot valve
FCF 80 flange 10.24" 10.24" 10.24" - via pilot valve
FCF-K 80 flange 7.09" - - - via pilot valve
FCF 100 flange 13.78" 13.78" 13.78" - via pilot valve
FCF-K 100 flange 9.45" - - - via pilot valve
FCF 125 flange 15.75" 15.75" 15.75" - via pilot valve
FCF-K 125 flange 11.81" - - - via pilot valve