home co-ax valves cx-tec valves case histories technical documents contact
orifice DN 10 - 15
pressure range 0 - 3000 psi
connection thread
function NC
valve normally closed
function NO
valve normally open
The valves' technical design is based on media and application requirements. This can lead to deviations from the general specifications shown on the data sheet with regards to the design, sealing materials and characteristics.
design externally controlled, with spring return
function NC - normally closed, NO - normally open
body materials aluminium, brass, stainless steel
seal materials PU, NBR, PTFE, PE, FPM, EPDM, HNBR, special seal materials
media gaseous, liquid, gelatinous, highly viscous, pasty, contaminated, abrasive
actuation pneumatic via 5/2-way pilot valve, hydraulic via 4/2-way control valve
actuator ports G 1/8 (pneumatic actuation), G 1/4 (hydraulic actuation, via adapter)
nominal voltage DC 24 V / AC 110 V / AC 230 V
electrical connection pilot valve plug acc. DIN EN 175301-803, form B, LED
enclosure protection IP 65
energized duty rating ED 100%
flow direction A B
B A
vacuum leak rate < 10-6 mbar·l·s-1
options valve body, function NO, damping, leak ports, limit switches, manual override, approvals, mounting, special voltage, coil M 12 x 1, explosion-proof, pilot valve
co-ax type orifice
mm
connection
thread NPT
connection
flange ANSI
pressure range
psi
Cv
value
media
temperature
ambient
temperature
switch time ms
open/close
PCD-1 10 DN 10 3/8 - 0 - 3000 3.49 -4°F ... 302°F -4°F ... 302°F 30-3000 / 30-3000
PCD-2 10 DN 10 3/8 - 0 - 3000 3.49 -4°F ... 302°F -4°F ... 302°F 30-3000 / 30-3000
PCD-1 15 DN 15 1/2 - 3/4 - 0 - 3000 6.98 -4°F ... 302°F -4°F ... 302°F 100-3000 / 100-3000
PCD-2 15 DN 15 1/2 - 3/4 - 0 - 3000 6.98 -4°F ... 302°F -4°F ... 302°F 100-3000 / 100-3000
PCS-1 10 DN 10 3/8 - 0 - 3000 3.49 -4°F ... 302°F -4°F ... 302°F 30-3000 / 30-3000
PCS-2 10 DN 10 3/8 - 0 - 3000 3.49 -4°F ... 302°F -4°F ... 302°F 30-3000 / 30-3000
PCS-1 15 DN 15 1/2 - 3/4 - 0 - 3000 6.98 -4°F ... 302°F -4°F ... 302°F 100-3000 / 100-3000
PCS-2 15 DN 15 1/2 - 3/4 - 0 - 3000 6.98 -4°F ... 302°F -4°F ... 302°F 100-3000 / 100-3000
PCS-3 15 DN 15 1/2 - 3/4 - 0 - 3000 6.98 -4°F ... 302°F -4°F ... 302°F 100-3000 / 100-3000
co-ax type connection standard 1 inductive
limit switch
2 inductive
limit switches
1 mechanical
limit switch
manual
override
PCD-1 10 thread 2.36" 2.36" 2.36" - via pilot valve
PCD-2 10 thread 2.36" 2.36" 2.36" - via pilot valve
PCD-1 15 thread 3.15" 3.15" 3.15" - via pilot valve
PCD-2 15 thread 3.15" 3.15" 3.15" - via pilot valve
PCS-1 10 thread 2.36" 2.36" 2.36" - via pilot valve
PCS-2 10 thread 2.36" 2.36" 2.36" - via pilot valve
PCS-1 15 thread 3.15" 3.15" 3.15" - via pilot valve
PCS-2 15 thread 3.15" 3.15" 3.15" - via pilot valve
PCS-3 15 thread 3.15" 3.15" 3.15" - via pilot valve
privacy policy & legal notice sitemap contact info@coaxvalves.com