orifice DN 2 - 6
pressure range 0 - 1950 psi
connection thread
function NC
valve normally closed
function NO
valve normally open
The valves' technical design is based on media and application requirements. This can lead to deviations from the general specifications shown on the data sheet with regards to the design, sealing materials and characteristics.
design direct acting, with spring return
function NC - normally closed, NO - normally open
body materials stainless steel
seal materials NBR, PTFE, FPM, EPDM
media gaseous, liquid
actuation DC direct current coil
AC direct current coil, with integrated / separated rectifier
nominal voltage DC 24 V / AC 110 V / AC 230 V
electrical connection plug acc. DIN EN 175301-803, form A, LED
insulation rating H 180°C
enclosure protection IP 65
energized duty rating ED 100%
flow direction A B
vacuum leak rate < 10-6 mbar·l·s-1
options function NO, approvals, mounting, special voltage, plug M 12 x 1
orifice DN 2 - 14
pressure range 0 - 6000 psi
connection thread
function NC
valve normally closed
 
 
The valves' technical design is based on media and application requirements. This can lead to deviations from the general specifications shown on the data sheet with regards to the design, sealing materials and characteristics.
design direct acting, with spring return
function NC - normally closed
body materials nickel plated steel, stainless steel
seal materials NBR, PTFE, FPM, special seal materials
media gaseous, liquid
actuation DC direct current coil
AC direct current coil, with integrated rectifier
nominal voltage DC 24 V / AC 110 V / AC 230 V
electrical connection plug acc. DIN EN 175301-803, form A, LED
insulation rating H 180°C
enclosure protection IP 65
energized duty rating ED 100%
flow direction A B
B A (upon request)
vacuum leak rate < 10-6 mbar·l·s-1
options special threads, 2-coil operation, approvals, special voltage, plug M 12 x 1, terminal box
orifice DN 8
pressure range 0 - 2400 psi
connection thread
function NC
valve normally closed
function NO
valve normally open
The valves' technical design is based on media and application requirements. This can lead to deviations from the general specifications shown on the data sheet with regards to the design, sealing materials and characteristics.
design pressure balanced, with spring return
function NC - normally closed, NO - normally open
body materials brass
seal materials NBR, PTFE, FPM
media emulsions / oils
actuation pneumatic via 5/2-way pilot valve
pilot valve interface NAMUR / ISO 1
nominal voltage DC 24 V / AC 110 V / AC 230 V
electrical connection pilot valve plug acc. DIN EN 175301-803, form B, LED
enclosure protection IP 65
energized duty rating ED 100%
flow direction A B
B A (without control pressure Δp 16 bar max.)
vacuum leak rate < 10-6 mbar·l·s-1
options function NO, damping, limit switches, manual override, special voltage, coil M 12 x 1, explosion-proof, pilot valve
orifice DN 15 - 50
pressure range 0 - 3000 psi
connection thread / flange
function NC
valve normally closed
function NO
valve normally open
The valves' technical design is based on media and application requirements. This can lead to deviations from the general specifications shown on the data sheet with regards to the design, sealing materials and characteristics.
design pressure balanced, with spring return
function NC - normally closed, NO - normally open
body materials galvanized steel, nickel plated steel, without non-ferrous metals, stainless steel
seal materials NBR, PTFE, FPM, CR, EPDM, special seal materials
media gaseous, liquid, gelatinous, highly viscous, pasty, contaminated, aggressive
actuation pneumatic via 5/2-way pilot valve, hydraulic via 4/2-way control valve
pilot valve interface NAMUR / ISO 1
nominal voltage DC 24 V / AC 110 V / AC 230 V
electrical connection pilot valve plug acc. DIN EN 175301-803, form B, LED
enclosure protection IP 65
energized duty rating ED 100%
flow direction A B
B A (without control pressure Δp 16 bar max.)
vacuum leak rate < 10-6 mbar·l·s-1
options special threads, special flanges, function NO, damping, flush ports, leak ports, limit switches, manual override, approvals, mounting, special voltage, coil M12x1, explosion-proof, pilot valve
orifice DN 15 - 50
pressure range 0 - 3000 psi
connection thread / flange
function NC
valve normally closed
function NO
valve normally open
The valves' technical design is based on media and application requirements. This can lead to deviations from the general specifications shown on the data sheet with regards to the design, sealing materials and characteristics.
design pressure balanced, with spring return, intersecting switch-over
function NC - normally closed (A B), NO - normally open (A B)
body materials galvanized steel, nickel plated steel, without non-ferrous metals, stainless steel
seal materials NBR, PTFE, FPM, CR, EPDM, special seal materials
media gaseous, liquid, gelatinous, highly viscous, pasty, contaminated, aggressive
actuation pneumatic via 5/2-way pilot valve, hydraulic via 4/2-way control valve
pilot valve interface NAMUR / ISO 1
nominal voltage DC 24 V / AC 110 V / AC 230 V
electrical connection pilot valve plug acc. DIN EN 175301-803, form B, LED
enclosure protection IP 65
energized duty rating ED 100%
flow direction A B / A C
B A (without control pressure Δp 16 bar max.)
vacuum leak rate < 10-6 mbar·l·s-1
options special threads, special flanges, function NO, damping, flush ports, leak ports, limit switches, manual override, approvals, mounting, special voltage, coil M12x1, explosion-proof, pilot valve
co-ax type orifice
mm
connection
thread NPT
connection
flange ANSI
pressure range
psi
Cv
value
media
temperature
ambient
temperature
switch time ms
open/close
A 45 DN 2 3/8 - 0 - 1950 0.09 14°F ... 176°F 14°F ... 176°F 20 / 45
A 45 DN 4 3/8 - 0 - 600 / 900 0.37 14°F ... 176°F 14°F ... 176°F 20 / 45
A 45 DN 6 3/8 - 0 - 150 0.68 14°F ... 176°F 14°F ... 176°F 20 / 45
KB 15 DN 2 3/8 - 0 - 4500 / 6000 0.12 -40°F ... 212°F -40°F ... 176°F 60 / 170
KB 15 DN 3 3/8 - 0 - 3750 / 4500 0.29 -40°F ... 212°F -40°F ... 176°F 60 / 170
KB 15 DN 4 3/8 - 0 - 1800 / 2250 0.77 -40°F ... 212°F -40°F ... 176°F 60 / 170
KB 15 DN 5 3/8 - 0 - 1200 / 1500 0.94 -40°F ... 212°F -40°F ... 176°F 60 / 170
KB 15 DN 6 3/8 - 0 - 750 / 1050 1.21 -40°F ... 212°F -40°F ... 176°F 60 / 170
KB 15 DN 8 3/8 - 0 - 450 / 600 1.67 -40°F ... 212°F -40°F ... 176°F 60 / 170
KB 20 DN 8 1/2 - 0 - 750 2.09 -40°F ... 212°F -40°F ... 176°F 120 / 270
KB 20 DN 10 1/2 - 0 - 525 2.91 -40°F ... 212°F -40°F ... 176°F 120 / 270
KB 20 DN 12 1/2 - 0 - 375 3.37 -40°F ... 212°F -40°F ... 176°F 120 / 270
KB 20 DN 14 1/2 - 0 - 225 3.72 -40°F ... 212°F -40°F ... 176°F 120 / 270
MCF-H 08 DN 8 3/8 - 0 - 2400 1.40 -4°F ... 320°F -4°F ... 320°F 30-3000 / 30-3000
VMK-H/VFK-H 15 DN 15 1/2 2500 / 3500 0 - 3000 6.51 -4°F ... 320°F -4°F ... 320°F 50-3000 / 50-3000
VMK-H/VFK-H 20 DN 20 3/4 2500 / 3500 0 - 3000 8.95 -4°F ... 320°F -4°F ... 320°F 50-3000 / 50-3000
VMK-H/VFK-H 25 DN 25 1 2500 / 3500 0 - 3000 14.65 -4°F ... 320°F -4°F ... 320°F 50-3000 / 50-3000
VMK-H/VFK-H 40 DN 40 1 1/2 2500 / 3500 0 - 3000 36.05 -4°F ... 320°F -4°F ... 320°F 100-3000 / 100-3000
VMK-H/VFK-H 50 DN 50 2 2500 / 3500 0 - 3000 50.00 -4°F ... 320°F -4°F ... 320°F 100-3000 / 100-3000
VMK-H/VFK-H 15 DR DN 15 1/2 2500 / 3500 0 - 3000 5.12 -4°F ... 320°F -4°F ... 320°F 50-3000 / 50-3000
VMK-H/VFK-H 20 DR DN 20 3/4 2500 / 3500 0 - 3000 8.84 -4°F ... 320°F -4°F ... 320°F 50-3000 / 50-3000
VMK-H/VFK-H 25 DR DN 25 1 2500 / 3500 0 - 3000 12.56 -4°F ... 320°F -4°F ... 320°F 50-3000 / 50-3000
VMK-H/VFK-H 40 DR DN 40 1 1/2 2500 / 3500 0 - 3000 36.05 -4°F ... 320°F -4°F ... 320°F 100-3000 / 100-3000
VMK-H/VFK-H 50 DR DN 50 2 2500 / 3500 0 - 3000 50.00 -4°F ... 320°F -4°F ... 320°F 100-3000 / 100-3000
co-ax type connection standard 1 inductive
limit switch
2 inductive
limit switches
1 mechanical
limit switch
manual
override
A 45 thread 4.45" - - - -
KB 15 thread 5.31" - - - -
KB 20 thread 6.30" - - - -
MCF-H 08 thread 4.72" 4.72" (Reed) 4.72" (Reed) - via pilot valve
VMK-H / VFK-H 15 thread / flange 7.68" / 10.43" 8.86" / 11.61" 8.86" / 11.61" 8.46" / 11.22" via pilot valve
VMK-H / VFK-H 20 thread / flange 8.46" / 11.34" 9.65" / 12.52" 9.65" / 12.52" - via pilot valve
VMK-H / VFK-H 25 thread / flange 9.06" / 12.01" 10.24" / 13.09" 10.24" / 13.09" - via pilot valve
VMK-H / VFK-H 40 thread / flange 12.28" / 15.16" 12.28" / 15.16" 12.28" / 15.16" - via pilot valve
VMK-H / VFK-H 50 thread / flange 12.28" / 15.16" 12.28" / 15.16" 12.28" / 15.16" - via pilot valve
VMK-H / VFK-H 15 DR thread / flange 8.86" / 12.32" 10.04" / 13.50" 10.04" / 13.50" - via pilot valve
VMK-H / VFK-H 20 DR thread / flange 10.12" / 14.37" 11.30" / 15.55" 11.30" / 15.55" - via pilot valve
VMK-H / VFK-H 25 DR thread / flange 10.43" / 14.57" - - - via pilot valve
VMK-H / VFK-H 40 DR thread / flange 15.75" / 19.69" 15.75" / 19.69" 15.75" / 19.69" - via pilot valve
VMK-H / VFK-H 50 DR thread / flange 15.75" / 19.69" 15.75" / 19.69" 15.75" / 19.69" - via pilot valve