| orifice |
|
DN 10 |
 |
| pressure range |
|
0 - 3000 psi |
 |
| connection |
|
thread |
 |
function NC valve normally closed
 |
 |
function NO valve normally open
 |
 |
| The valves' technical design is based on media and application requirements. This can lead to deviations from the general specifications shown on the data sheet with regards to the design, sealing materials and characteristics. |
|
|
 |
 |
| design |
pressure balanced, with spring return |
 |
| function |
NC - normally closed, NO - normally open |
 |
| body materials |
brass, stainless steel |
 |
| seal materials |
NBR, PTFE, FPM, CR, EPDM |
 |
| media |
gaseous, liquid |
 |
| actuation |
DC direct current coil
AC direct current coil, with integrated rectifier |
 |
| nominal voltage |
DC 24 V / AC 110 V / AC 230 V |
 |
| electrical connection |
plug acc. DIN EN 175301-803, form A, LED |
 |
| insulation rating |
H 180°C |
 |
| enclosure protection |
IP 65 |
 |
| energized duty rating |
ED 100% |
 |
| flow direction |
A B B A (upon request) |
 |
| vacuum |
leak rate < 10-6 mbar·l·s-1 |
 |
| options |
function NO, limit switches, special voltage, plug M 12 x 1, terminal box |
 |
|
  |
 |
 |
| orifice |
|
DN 10 |
 |
| pressure range |
|
0 - 2250 psi |
 |
| connection |
|
thread |
 |
function NC valve normally closed
 |
 |
function NO valve normally open
 |
 |
| The valves' technical design is based on media and application requirements. This can lead to deviations from the general specifications shown on the data sheet with regards to the design, sealing materials and characteristics. |
|
|
 |
 |
| design |
pressure balanced, with spring return, intersecting switch-over |
 |
| function |
NC - normally closed (A B), NO - normally open (A B) |
 |
| body materials |
brass, stainless steel |
 |
| seal materials |
NBR, PTFE, FPM, CR, EPDM |
 |
| media |
gaseous, liquid |
 |
| actuation |
DC direct current coil AC direct current coil, with integrated rectifier |
 |
| nominal voltage |
DC 24 V / AC 110 V / AC 230 V |
 |
| electrical connection |
plug acc. DIN EN 175301-803, form A, LED |
 |
| insulation rating |
H 180°C |
 |
| enclosure protection |
IP 65 |
 |
| energized duty rating |
ED 100% |
 |
| flow direction |
A B / A C B A / C A (upon request) |
 |
| vacuum |
leak rate < 10-6 mbar·l·s-1 |
 |
| options |
function NO, limit switches, special voltage, plug M 12 x 1, terminal box |
 |
|
  |
 |
 |
| orifice |
|
DN 1.5 - 3 |
 |
| pressure range |
|
0 - 7500 psi |
 |
| connection |
|
thread |
 |
function NC valve normally closed
 |
 |
function NO valve normally open
 |
 |
| The valves' technical design is based on media and application requirements. This can lead to deviations from the general specifications shown on the data sheet with regards to the design, sealing materials and characteristics. |
|
|
 |
 |
| design |
direct acting, with spring return |
 |
| function |
NC - normally closed, NO - normally open |
 |
| body materials |
brass, nickel plated brass, stainless steel |
 |
| seal materials |
NBR, FPM |
 |
| media |
gaseous, liquid |
 |
| actuation |
DC direct current coil AC direct current coil, with integrated rectifier |
 |
| nominal voltage |
DC 24 V / AC 110 V / AC 230 V |
 |
| electrical connection |
plug acc. DIN EN 175301-803, form A, LED |
 |
| insulation rating |
H 180°C |
 |
| enclosure protection |
IP 65 |
 |
| energized duty rating |
ED 100% |
 |
| flow direction |
A B |
 |
| vacuum |
leak rate < 10-6 mbar·l·s-1 |
 |
| options |
special threads, function NO, approvals, mounting, special voltage, plug M 12 x 1, terminal box |
 |
|
  |
 |
 |
| orifice |
|
DN 10 + 15 |
 |
| pressure range |
|
0 - 7500 psi |
 |
| connection |
|
thread |
 |
function NC valve normally closed
 |
 |
function NO valve normally open
 |
 |
| The valves' technical design is based on media and application requirements. This can lead to deviations from the general specifications shown on the data sheet with regards to the design, sealing materials and characteristics. |
|
|
 |
 |
| design |
pressure balanced, with spring return |
 |
| function |
NC - normally closed, NO - normally open |
 |
| body materials |
brass, stainless steel |
 |
| seal materials |
NBR, PTFE, FPM, CR, EPDM |
 |
| media |
gaseous, liquid |
 |
| actuation |
pneumatic via 5/2-way pilot valve |
 |
| actuation ports |
G 1/8 |
 |
| nominal voltage |
DC 24 V / AC 110 V / AC 230 V |
 |
| electrical connection pilot valve |
plug acc. DIN EN 175301-803, form B, LED |
 |
| enclosure protection |
IP 65 |
 |
| energized duty rating |
ED 100% |
 |
| flow direction |
A B B A (upon request) |
 |
| vacuum |
leak rate < 10-6 mbar·l·s-1 |
 |
| options |
function NO, damping, limit switches, special voltage, coil M 12 x 1, explosion-proof, pilot valve |
 |
|
  |
 |
 |
| orifice |
|
DN 10 + 15 |
 |
| pressure range |
|
0 - 7500 psi |
 |
| connection |
|
thread |
 |
function NC valve normally closed
 |
 |
function NO valve normally open
 |
 |
| The valves' technical design is based on media and application requirements. This can lead to deviations from the general specifications shown on the data sheet with regards to the design, sealing materials and characteristics. |
|
|
 |
 |
| design |
pressure balanced, with spring return, intersecting switch-over |
 |
| function |
NC - normally closed (A B), NO - normally open (A B) |
 |
| body materials |
brass, stainless steel |
 |
| seal materials |
NBR, PTFE, FPM, CR, EPDM |
 |
| media |
gaseous, liquid |
 |
| actuation |
pneumatic via 5/2-way pilot valve |
 |
| actuation ports |
G 1/8 |
 |
| nominal voltage |
DC 24 V / AC 110 V / AC 230 V |
 |
| electrical connection pilot valve |
plug acc. DIN EN 175301-803, form B, LED |
 |
| enclosure protection |
IP 65 |
 |
| energized duty rating |
ED 100% |
 |
| flow direction |
A B / A C B A (upon request) |
 |
| vacuum |
leak rate < 10-6 mbar·l·s-1 |
 |
| options |
function NO, damping, limit switches, special voltage, coil M 12 x 1, explosion-proof, pilot valve |
 |
|
  |
 |
| co-ax type |
orifice mm |
connection thread NPT |
connection flange ANSI |
pressure range psi |
Cv value |
media temperature |
ambient temperature |
switch time ms open/close |
 |
ECD-H 10 |
DN 10 |
3/8 |
- |
0 - 2250 / 3000 |
1.74 |
-4°F ... 320°F |
-4°F ... 140°F |
250 / 110 |
 |
ECD-H 10 DR |
DN 10 |
3/8 |
- |
0 - 2250 |
1.74 |
-4°F ... 320°F |
-4°F ... 140°F |
250 / 110 |
 |
KBS 15 |
DN 1.5 |
3/8 |
- |
0 - 7500 |
0.08 |
-40°F ... 212°F |
-40°F ... 176°F |
60 / 160 |
 |
KBS 15 |
DN 2 |
3/8 |
- |
0 - 6000 |
0.09 |
-40°F ... 212°F |
-40°F ... 176°F |
60 / 160 |
 |
KBS 15 |
DN 3 |
3/8 |
- |
0 - 3750 |
0.36 |
-40°F ... 212°F |
-40°F ... 176°F |
60 / 160 |
 |
PCD 10 |
DN 10 |
3/8 |
- |
0 - 3750 |
1.74 |
14°F ... 302°F |
14°F ... 302°F |
30-3000 / 30-3000 |
 |
PCD-H 10 |
DN 10 |
3/8 |
- |
0 - 7500 |
1.74 |
14°F ... 302°F |
14°F ... 302°F |
30-3000 / 30-3000 |
 |
PCD-H 15 |
DN 15 |
1/2 - 3/4 |
- |
0 - 7500 |
4.07 |
14°F ... 302°F |
14°F ... 302°F |
30-3000 / 30-3000 |
 |
PCD 10 DR |
DN 10 |
3/8 |
- |
0 - 3750 |
1.74 |
14°F ... 302°F |
14°F ... 302°F |
30-3000 / 30-3000 |
 |
PCD-H 10 DR |
DN 10 |
3/8 |
- |
0 - 7500 |
1.74 |
14°F ... 302°F |
14°F ... 302°F |
30-3000 / 30-3000 |
 |
PCD-H 15 DR |
DN 15 |
1/2 - 3/4 |
- |
0 - 7500 |
4.07 |
14°F ... 302°F |
14°F ... 302°F |
30-3000 / 30-3000 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
|
  |
 |
| co-ax type |
connection |
standard |
1 inductive limit switch |
2 inductive limit switches |
1 mechanical limit switch |
manual override |
 |
ECD-H 10 |
thread |
2.76" |
- |
- |
- |
- |
 |
ECD-H 10 DR |
thread |
2.76" |
- |
- |
- |
- |
 |
KBS 15 |
thread |
2.36" |
- |
- |
- |
- |
 |
PCD 10 |
thread |
2.76" |
- |
- |
- |
via pilot valve |
 |
PCD-H 10 |
thread |
3.15" |
- |
- |
- |
via pilot valve |
 |
PCD-H 15 |
thread |
3.94" |
- |
- |
- |
via pilot valve |
 |
PCD 10 DR |
thread |
2.76" |
- |
- |
- |
via pilot valve |
 |
PCD-H 10 DR |
thread |
3.15" |
- |
- |
- |
via pilot valve |
 |
PCD-H 15 DR |
thread |
3.94" |
- |
- |
- |
via pilot valve |
 |
 |
 |
 |
 |
 |
 |
 |
|
 |
 |
 |
 |
 |
|
 |