In the following we have compiled some calculation options for you. For liquids and gases it is possible to calculate the kv value, the flow Q and the pressure drop Δp.

With the calculations for gases, one additionally distinguishes between the under-critical (p2 > p1/2) and over-critical cases (p2 < p1/2).
All calculations are purely practical formulas, i.e. simplifications for the respective case, which may only be used with the specified units.
 
kv value
In order to calculate the kv value the flow Q, the density ρ1 of the media at the valve inlet and the pressure drop (Δp) across the valve must be known:
Q = m³/h = m³/h  
ρ1 = kg/m³
Δp = bar
flow
In order to calculate the flow Q the kv value, the density ρ1 of the media at the valve inlet and the pressure drop (Δp) across the valve must be known:
kv = m³/h = m³/h  
ρ1 = kg/m³
Δp = bar
pressure drop
In order to measure the pressure drop Δp the kv value, the density ρ1 of the media at the valve inlet and the flow Q must be known:
kv = m³/h = bar  
ρ1 = kg/m³
Q = m³/h
 
kv value
In order to calculate the kv value the volumetric flow Qn at 1013 hPa and 0°C, the standard density ρn of the media, the pressure drop (Δp) across the valve, the media pressure p2 downstream of the valve and the media temperature at the valve inlet must be known:
Qn = Nm³/h = m³/h
ρn = kg/Nm³
Δp = bar
p2 = bar = m³/h
T1 =
°C
°F
flow
In order to calculate the flow Qn the kv value, the standard density ρn of the media, the pressure drop (Δp) across the valve, the media pressure p2 downstream of the valve and the media temperature at the valve inlet must be known:
kv = m³/h = Nm³/h
ρn = kg/Nm³
Δp = bar
p2 = bar = Nm³/h
T1 =
°C
°F
pressure drop
In order to calculate the pressure drop Δp the kv value, the volumetric flow Qn at 1013 hPa and 0°C, the standard density ρn of the media, the media pressure p2 downstream of the valve and the media temperature at the valve inlet must be known:
kv = m³/h = bar
Qn = Nm³/h
ρn = kg/Nm³
p2 = bar     if
T1 =
°C
°F
 
direct acting valves
2/2 way 3/2 way
NC


NO


NC
only one flow
direction
NO
only one flow
direction
NC


NO


IV 10 / 16-3


dxf-download dxf-download dxf-download dxf-download
 
externally controlled valves - pneumatic
2/2 way 3/2 way
NC NO NC NO
dxf-download dxf-download
dxf-download dxf-download
 
externally controlled valves - hydraulic
2/2 way 3/2 way
NC NO NC NO
dxf-download dxf-download
 
control valves
pressure limitation valves
SPB 08 SPB 65 HPB 08 3-HPB 08 HPB 65 3-HPB 65
dxf-download dxf-download dxf-download dxf-download
SPB-N 15 SPB-S 15, SPB-H 15 3-HPB-N 15 3-HPB-S 15, 3-HPB-H 15
dxf-download dxf-download dxf-download dxf-download
 
pressure reduction valves pressure control valves flow control valves
SPI 08, SPP 15, SPI 32 HPI 08, HPP 15, HPI 32 3-HPI 08, 3-HPP 15, 3-HPI 32 SPP 15 DR RMQ
dxf-download dxf-download dxf-download dxf-download
 
pilot valves
5/2 way pilot valve

5/2 way pilot valve
impulse controlled
3/2 way pilot valve
main valve monostable
dxf-download dxf-download dxf-download
 
privacy policy & legal notice sitemap contact info@coaxvalves.com